Detailat
A-DT-504 · Roof waterproofing (inverted roof)

A-DT-504 · v0.1 · Draft

Roof waterproofing (inverted roof)

A 3D section of a concrete roof with a parapet: screed to falls, a fillet, two 4 mm bitumen membranes turned up the parapet with a termination bar and counter-flashing, then 50 mm XPS, geotextile and gravel ballast, and a drain with a clamping ring. Every part has a name and a function.

Full screen ⤢

Parts of the detail

  1. 01
    Concrete roof slab

    The structure under every layer.

  2. 02
    Screed to falls, about 1.5%

    About 70 mm at the parapet, thinning towards the drain.

  3. 03
    50×50 fillet

    Removes the sharp corner under the membrane at the parapet.

  4. 04
    Primer

    Prepares the surface so the membrane bonds.

  5. 05
    Two 4 mm bitumen membranes

    Torch-applied with offset laps, turned up the parapet more than 150 mm above the finished surface.

  6. 06
    Termination bar and sealant

    Hold the top of the membrane on the parapet and seal it.

  7. 07
    Counter-flashing in a chase

    Covers the membrane top and sheds water clear.

  8. 08
    Drain with clamping ring

    The membrane is clamped onto the drain flange, with a gravel guard on top.

  9. 09
    Protection layer

    Between the membrane and everything above it.

  10. 10
    50 mm XPS insulation

    In an inverted roof it sits above the membrane and shields it from heat.

  11. 11
    Geotextile

    Filter layer between insulation and gravel.

  12. 12
    50 mm gravel

    Ballast that holds the insulation down and shades it.

  13. 13
    Coping

    Caps the parapet, sloped towards the roof, with drips.